1#RTO
Source of waste gas: reaction kettle, production line and oil storage tank
Design air volume: 35000 M ³/ h
Waste gas concentration: about 500mg/m3
Waste gas components: non methane total hydrocarbon, asphalt smoke, particulate matter and benzopyrene
Process scheme: cyclone separator + tower filtration + Rotary Valve RTO
RTO MODEL: 35000Nm³/h(negative pressure)
Emission Limits: NMHC≤ 24mg/m3
2#RTO
Source of waste gas: reaction kettle, production line and oil storage tank
Design air volume: 50000 M ³/ h
Waste gas concentration: about 500mg/m3
Waste gas components: non methane total hydrocarbon, asphalt smoke, particulate matter and benzopyrene
Process scheme: cyclone separator + tower filtration + Rotary Valve RTO
RTO MODEL: 50000Nm³/h(negative pressure)
Emission Limits: NMHC≤ 24mg/m3