HOME >> Case >> Printing Industry
Source of waste gas: organized waste gas from printing machines and compound machines and unorganized waste gas from workshops
Design air volume: 2 sets 60000 m³/h Rotary Valve RTO
Waste gas concentration: about 3000mg/m3-5000mg/m3, unorganized 600mg/m3
Waste gas components: ethyl acetate, n-propyl ester, isopropanol, etc
Process scheme: air reduction and concentration + Rotary Valve RTO + waste heat recovery (with steam waste heat boiler)
RTO MODEL: 2 sets 60000 m³/h
Emission Limits: NMHC≤ 50mg/m3
Address:16-17 floors, Building B, Zhengheng Financial Plaza, No. 391, Yanta South Road, Aerospace Base, Xi’an City, Shaanxi Province
Address:Address:No. 15 Weihui Road, Yangling Demonstration Zone, Shaanxi Province
Tel: +86-029-89689287(FAX)
Whatsapp:+8615598869179
E-Mail:yurcentexport@163.com
Website:www.yurcent.com